Atop Industrial Wireless Serial Device Server Series
SW550X
User Manual V 1.1
75
4.2.10 TCP Server Application: Multi-Point TCP Pair Connections
The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection
is that the TCP implementation would also exchange flow control pins for RS-232. However,
the TCP Server is limited to a maximum of four connections. If there are four serial devices and
they don’t use flow control pins with RS-232 or RS-485, it is possible to setup pair connection
in UDP mode, Sec. 4.2.8. After multi-connection is enabled in the WebUI, refer to the following
table to setup Pair Connection as in Fig. 4. 18.
Table 4. 2
IP Address
Link Mode
Application
Local Listening
Port
Destination
IP
Destination
Port
SW5501 Master COM1
10.0.50.100
TCP Server
Pair Connection Master
4660
-
-
SW5502 Slave 1 COM1
10.0.50.200
TCP Client
Pair Connection Slave
-
10.0.50.100
4660
SW5502 Slave 1 COM2
10.0.50.200
TCP Client
Pair Connection Slave
-
10.0.50.100
4660
SW5501 Slave 2 COM1
10.0.50.201
TCP Client
Pair Connection Slave
-
10.0.50.100
4660
SW5501 Slave 3 COM1
10.0.50.202
TCP Client
Pair Connection Slave
-
10.0.50.100
4660
Fig. 4. 18