Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
44
Fig. 2.39.a
Table 2.23
2.9.1 Community Strings
EH7510 supports SNMP V1, V2c, and V3; V1 and V2c use a community string match for
authentication; there are three levels of authentications which are read-sysinfo-only, read-
all-only, or read-write-all. For example, in our default setting, the SNMP agent can access
all objects with read-all-only permissions using the string public. Another example is that the
string private has permission of read-write-all.
This option allows users to use a community string match for authentication; users can
specify the string names and the type of permissions on the String field, Fig. 2.39.a.
Label
Description
Factory Default
SNMP
Choose to enable SNMP V1/V2c/V3.
Disabled