A.2. Software Specification
Item Specifications
Protocol
TCP, UDP, ARP, ICMP, SNMP, HTTP, Telnet, BOOTP, DHCP
Configuration
y Configuration information for both TCP/IP and serial ports is written in
the EEPROM.
y Configuration utilities of Windows 98/2000/NT/XP/2003 are provided.
Internal Buffer Size
y TCP receiving buffer size = 8K bytes
y TCP transmitting buffer size = 16K bytes
y RS-232 or RS-485/RS-422 receiving buffer size = 4K bytes
y RS-232 or RS-485/RS-422 transmitting buffer size = 4K bytes
A.3 Panel Layout and Connector Pin Assignments
A.3.1. Panel Layout
A.3.1.1 DB9 for SE5002 (RS-232/RS-422/RS-485)