Atop-technology SE5002D User manual Instrukcja Użytkownika Strona 54

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 87
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 53
Atop Serial Device Server
SE5002D
User Manual V. 1.1
3.5.6 Multi-Point TCP Pair Connections
The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection
is that the TCP implementation would also exchange flow controls pins of RS-232. However,
the TCP Server is limited to a maximum of four connections. If there are than four serial
devices and does not use flow control pins of RS-232, it is possible to setup pair connection in
UDP mode, Sec. 3.6.3. After multi-connection is enabled in the WebUI, refer to the following
table to setup Pair Connection as in Fig. 3. 31.
Table 3. 2
IP Address
Link Mode
Local Listening Port
Destination IP
Destination Port
SE5002D Master COM1
10.0.50.100
TCP Server
5000
-
-
SE5002D Slave 1 COM1
10.0.50.200
TCP Client
-
10.0.50.100
5000
SE5002D Slave 1 COM2
10.0.50.200
TCP Client
-
10.0.50.100
5000
SE5002D Slave 2 COM1
10.0.50.201
TCP Client
-
10.0.50.100
5000
SE5002D Slave 2 COM2
10.0.50.201
TCP Client
-
10.0.50.100
5000
Fig. 3. 31
Przeglądanie stron 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 86 87

Komentarze do niniejszej Instrukcji

Brak uwag