Atop Serial Device Server
SE5002D
User Manual V. 1.1
Press any key to continue.
An editor will open dapdl.cfg automatically. Edit the content to match the SE5002Ds IP
address and the new firmware file name; dapl.cfg has the following structure.
Remote_IP
10.0.50.100
Load
Firmware.hex
The first line identifies the SE5002Ds IP address, the second line indentifies the firmwares
name (.hex) to be downloaded.
Fig. 2
File Save to save the file.
File Exit to exit the text editor.
Enter the admin as the user ID and the password for SE5002D. If a password is not set,
pres enter. The batch file will upgrade the system firmware. SE5002D will automatically
restart after the new firmware is uploaded.